How to determine if the output shaft of FF series hard tooth gear reducer is bent
The following are specific judgment steps and standards:
1、 Preliminary judgment during operation (see, listen, touch)
During the operation of the device, if the output shaft bends, the following obvious symptoms are usually accompanied:
Abnormal vibration and noise: The gearbox body experiences severe vibration accompanied by irregular periodic metal friction sounds or abnormal noises.

Abnormal temperature rise: Shaft bending can cause uneven bearing force and increased friction on the shaft. If the temperature of the output end bearing seat is found to be far beyond the normal range (such as exceeding 80 ℃ during operation) when touched by hand or using a thermometer, it is highly suspected that the shaft is deformed.
Unstable transmission and shaft shifting: Abnormal axial movement (shaft shifting) of the output shaft, or obvious pulsation and fluctuating speed when driving the load.
Shaft end oil leakage: Bending of the shaft can cause uneven stress or lip deformation on the skeleton oil seal at the shaft extension end, leading to oil leakage.
2、 Precise measurement after shutdown (diagnostic core)
It is usually difficult for the naked eye to directly see the slight bending of the shaft, and professional tools must be used for "marking" measurement:
1. Preparation tools: Prepare a magnetic gauge holder and a dial indicator (or micrometer).
2. Fixed gauge holder: firmly attach the magnetic gauge holder to the gearbox housing or a stationary reference surface to ensure that there is no displacement during the measurement process.
3. Arrange measuring points:
Radial runout measurement: Place the measuring head of the dial gauge vertically against the outer surface of the output shaft. Suggest taking 2-3 points at both ends and in the middle (or neck) of the shaft for measurement.
End face runout measurement: Place the dial gauge probe on the end face of the output shaft to detect the end face swing of the shaft.
4. Turning reading: Slowly and uniformly manually rotate the output shaft for a full circle (360 degrees), carefully observe and record the difference between the maximum and minimum readings of the dial gauge pointer (i.e. jumping/swinging amplitude).
3、 Judgment criteria and subsequent processing
Based on the measured jumping data from the table, a final judgment can be made and a repair plan can be decided:
Normal range: The general runout is within 1-2 threads (0.01~0.02mm), which belongs to normal assembly and processing errors and does not affect use.
Slight bending (≤ 0.2mm): If the jumping amount exceeds the normal range but is within 0.2mm, it can usually be repaired by cold straightening method (using V-shaped iron to apply reverse pressure on the press) or polishing.
Severe bending (>0.2mm): If the bending amount is large, or if obvious cracks or wear marks are found on the shaft surface during marking, forced straightening can easily lead to metal fatigue fracture. It is recommended to replace the shaft directly with a new one.