Four Sea Ltd
sales@reducersgearboxes.com
Home      Products     High Voltage Motors      Y Series HV Motors       1250kW AC Squirrel Cage Asynchronous Mot
  • 1250kW AC Squirrel Cage Asynchronous Motor for Blower Application
1250kW AC Squirrel Cage Asynchronous Motor for Blower Application

1250kW AC Squirrel Cage Asynchronous Motor for Blower Application

Product Highlights

High Efficiency & Energy Saving: Low-loss silicon steel sheets and optimized electromagnetic design cut energy consumption and boost power density. Superior Insulation Performance: Stator windings adopt Class F insulation with VPI vacuum pressure impregnation treatment, delivering outstanding moisture resistance and dielectric stability. Wide Power Coverage: Power ratings up to 25,000 kW, frame sizes ranging from 315 mm to 1120 mm. Multiple Voltage Options: Compatible with 3.3kV, 6kV, 6.6kV, 10kV, 11kV and 13.8kV. Dependable Bearing Assembly: Equipped with SKF bearings fitted with on-line oil filling and draining fittings, enabling lubrication maintenance without shutdown. Proven Worldwide Performance: Over 30 years of manufacturing experience, exported to more than 40 countries, compliant with IEC and GB standards. Flexible Protection Classes: IP23, IP44, IP54, IP55, IP56 and IPW24 available to match diverse site environments. Diversified Cooling Schemes: IC01, IC611 and IC81W cooling methods configurable for different thermal load requirements.

Product Attributes

Item Specification Item Specification
Customization Available Rated Power Up to 25000 kW
Frequency 50Hz, 60Hz Model NO. Y500-4-1250KW
Voltage 3.3kV, 6kV, 6.6kV, 10kV, 11kV, 13.8kV Frame Size 315-1120mm
Cooling Method IC01 Mounting IM1001
Rotation Direction CW / CCW Duty Type S1
Insulation Class F Protection Class IP23
Ambient Temperature -20℃ ~ 40℃ Installation Site Indoor / Outdoor
Bearing Brand SKF Space Heater Yes
Transport Package Standard Seaworthy Packing Trademark CHANGLI
Origin China HS Code 8501530090
Production Capacity 500000 sets per year - -

Product Description

Y series high voltage three-phase induction motors were developed and upgraded based on technology introduced in the 1980s, with over 30 years of iteration. With continuous improvements in insulation materials, adoption of low-loss silicon steel sheets and repeated electromagnetic optimization, the motor achieves reduced losses and higher power output. Drawing on 60 years of experience in high voltage induction motor design and fabrication, we have completed the latest round of optimization to satisfy domestic and industrial market demands. Verified by type tests, this series reaches or approaches international advanced standards in both technical and economic performance. Mass-produced and widely supplied across China, these motors have been exported to over 40 countries and regions covering Europe, America, Africa and other areas, earning consistent positive feedback from end users.

Manufactured with premium raw materials and mature production processes, this motor series features high efficiency, low vibration, stable operation and easy installation and maintenance. Its power grades, electrical characteristics, mounting dimensions and tolerances conform to GB755, IEC 60034-1 and relevant machinery industry standards.

In line with GB4942.1 and IEC 60034-5, available enclosure protection grades include IP23, IP44, IP54, IP55 and IP56. IP23 motors can be converted to IP44 (pipe ventilation) or IPW24 (weather protected type). Custom protection classes are available upon request.

Three cooling options are offered per GB/T1993 and IEC 60034-6: IC01, IC611 and IC81W. Other cooling configurations can be customized according to customer requirements.

The standard construction and mounting form is IMB3 (horizontal foot-mounted), complying with GB997 and IEC 60034-7. Based on rotor type, protection class and cooling method, the series is divided into eight sub-models as shown below:


Model Protection Class Cooling Method Rotor Type
Y IP23 IC01 Squirrel Cage Rotor
YR IP23 IC01 Wound Rotor
YQF IPW24 IC01 Squirrel Cage Rotor
YRQF IPW24 IC01 Wound Rotor
YKS IP44 / IP54 / IP55 / IP56 IC81W Squirrel Cage Rotor
YRKS IP44 / IP54 / IP55 / IP56 IC81W Wound Rotor
YKK IP44 / IP54 / IP55 / IP56 IC611 Squirrel Cage Rotor
YRKK IP44 / IP54 / IP55 / IP56 IC611 Wound Rotor

Technical data and installation dimensions for 10kV motors in all frame sizes can be adapted for 3kV, 10.5kV and 11kV versions.

Application

This motor series drives general machinery such as compressors, blowers, water pumps, feeders and conveyors, serving as prime movers for mines, machinery plants, petrochemical facilities and power stations. For loads with high inertia including blowers, coal mills, rolling mills, crushers and belt conveyors, customers shall provide full technical data and sign a technical agreement with us for dedicated design, ensuring reliable motor operation.

Normal Operating Conditions

  1. Altitude ≤ 1000 m above sea level
  2. Maximum ambient temperature ≤ 40℃; minimum ambient temperature: -15℃ for rolling bearing motors, 5℃ for sliding bearing motors; YKS and YRKS minimum ambient temperature: 5℃
  3. For YKS / YRKS water-cooled motors: cooling water inlet temperature 5℃ ~ 33℃
  4. Monthly average maximum relative humidity ≤ 90% with monthly average minimum temperature ≤ 25℃ in humid months
  5. Power frequency: 50Hz ±1%
  6. Operating voltage deviation: within ±5% of rated voltage
  7. Duty: S1 continuous operation

Construction Description

Y and YR are the base models with IP23 protection and IC01 cooling. Derivative variants cover YKS (air-water cooled), YQF (weather protected), YKK (air-air cooled), YRKS, YRQF and YRKK.

The motor adopts a widely used box-type structure. The frame and end shields are steel plate welded for high rigidity and lightweight design. After removing the protective cover or cooler, internal components are accessible for convenient inspection, installation and maintenance. The stator adopts external pressing structure. Stator windings use Class F insulation and anti-corona materials with reliable special binding for terminal fixing. The whole stator undergoes VPI solventless impregnation, delivering stable insulation, moisture resistance and impulse withstand capability.

Squirrel cage rotors are mostly cast aluminum type with proven fracture-free reliability. Copper bar squirrel cage rotors use advanced slot welding and fixing technology. Wound rotors are fitted with Class F insulation and processed by VPI.

Bearings are rolling type or sliding type, selected according to motor power and speed. Base bearing protection grade is IP44 and upgraded for higher motor enclosure ratings. Rolling bearing versions are equipped with on-line oil filling and draining ports, supporting lubricant refill and discharge without equipment shutdown.

The main terminal box is sealed to IP54. It is mounted on the non-drive side (viewed from shaft extension) as standard and can be relocated to the opposite side on request. Cable entry direction can be adjusted to top, bottom, left or right. An independent grounding terminal is integrated inside the box.

Starting Requirements for Y, YKS, YQF, YKK Induction Motors

Rotor thermal and stress simulation is completed via computer calculation to avoid premature damage caused by heavy starting loads. Customers need to comply with the following requirements:

  1. Total inertia of driven equipment (converted to motor speed) shall not exceed the allowable load inertia listed in technical datasheets
  2. Terminal voltage during starting shall not drop below 85% of rated voltage The above applies for loads with quadratic torque characteristics such as pumps and fans.

Under these conditions, the motor permits two successive cold starts or one hot start, with natural coast-down between attempts. Further restarting is allowed after a 1-hour cooling interval. Contact our engineering team for custom design if driven inertia exceeds the limit, frequent starting is required or heavy-load starting is needed.

Detailed Photos

AC Squirrel Cage Induction Motor for Blower 1250kW AC Squirrel Cage Induction Motor for Blower 1250kW AC Squirrel Cage Induction Motor for Blower 1250kW

Product Parameters

Frame Size: H355-1120 Rated Voltage: 3KV, 3.3KV, 5.5KV, 6KV, 6.6KV, 10KV, 11KV, 13.8KV Poles: 2P,4P,6P,8P,10P,12P,14P,16P Protection Degree: IP23, IPW24 Mounting: IMB3, IMB35, IMB5, IMV1 etc. Power Range: up to 25000kW Frequency: 50Hz, 60Hz Cooling Method: IC01

Certifications

AC Squirrel Cage Induction Motor for Blower 1250kW AC Squirrel Cage Induction Motor for Blower 1250kW AC Squirrel Cage Induction Motor for Blower 1250kW AC Squirrel Cage Induction Motor for Blower 1250kW AC Squirrel Cage Induction Motor for Blower 1250kW AC Squirrel Cage Induction Motor for Blower 1250kW

Packaging & Shipping

AC Squirrel Cage Induction Motor for Blower 1250kW AC Squirrel Cage Induction Motor for Blower 1250kW AC Squirrel Cage Induction Motor for Blower 1250kW Standard seaworthy export packing Plywood case or fumigated wooden case Suitable for long-distance sea transportation

Quality Control

In-process Inspection

All measuring instruments are calibrated annually. Every component goes through dedicated inspection:


Part Inspection Items
Coil 1. Raw material physical & chemical test2. Winding process audit3. Winding dimension check
Iron Core 1. Silicon steel sheet material report2. Lamination burr & coating inspection3. Stack dimension verification
Frame 1. Weld quality certificate2. Machining tolerance inspection
Rotor 1. Core stacking inspection2. Conductor bar welding check3. Bar & end ring material, appearance, conductivity and dimension test4. Slot bar fastening check5. Outer diameter and overall dimension check6. Dynamic balancing
Shaft 1. Raw material and annealing inspection2. Finishing dimension check
Stator 1. Core compactness test2. Core length and segment length check3. Winding insertion inspection4. Iron loss test
Assembly 1. Bearing size and surface quality check2. Air gap, stator-rotor alignment, fan and baffle clearance check3. Internal cleaning inspection4. Shaft height and mounting dimension verification
Test 1. Routine test2. Type test

Every motor is fully tested before shipment and delivered with an official test report.

Routine Test Items

Winding three-phase DC resistance Winding insulation resistance to earth Winding withstand voltage test No-load current No-load power No-load loss Three-phase no-load current unbalance Locked rotor current Locked rotor torque Maximum torque Rotation direction Vibration (horizontal, vertical, axial) Noise

Type Test Items

Full load input power Full load current Stator winding loss Rotor winding loss Iron loss Mechanical loss Stray load loss Full load slip Stator winding temperature rise Bearing temperature Hot insulation resistance Overload test Full load power factor Efficiency

Warranty Period

Standard warranty: 12 months after commissioning or 18 months after delivery, whichever comes first. Extended warranty is available upon request. Please contact us for details.

CATEGORIES

CONTACT US

  Name: Hu Bo

  phone:+8618881888393

  Whatsapp:+8618881888393

  Email:sales@reducersgearboxes.com

  Add:No. 10 Xiyuan Road, Hangzhou City, Zhejiang Province, China

whatsapp

Skype

Email

Phone

Leave a message