Precautions for shaft alignment adjustment of ZD15-4.5-5 soft tooth surface reducer
1、 Pre prevention and control measures before adjustment
Eliminate soft foot hazards: Use a feeler gauge to check the contact between the reducer, motor base, and foundation. All feet should not be suspended, and the single foot gap should be ≤ 0.03mm to avoid force rebound after adjustment.
Verify basic accuracy: Use a precision level to measure the levelness of the gearbox body, with a deviation of ≤ 0.1mm/m, and ensure that the installation surface is free of burrs, oil stains, and rust.
Calibration measurement tool: Verify the accuracy of the dial gauge to within 0.01mm in advance to avoid tool errors that may cause adjustment errors.
Check the status of the components: Check that the coupling is not worn or deformed, the shaft end is not bumped or damaged, and confirm that the shaft itself has no bending defects.

2、 Step by step calibration with strict tolerance control
Coarse centering positioning: Use a ruler to lean against the outer circle of the two halves of the coupling, and control the height difference of the outer circle within 0.1mm by adding or removing shims; Measure the distance between the end faces with a caliper to ensure that the gap difference between the end faces is ≤ 0.2mm.
Precision locking for precise alignment: Priority should be given to using the dial gauge dual gauge method. The radial and axial gauges should be installed at a 90 ° angle, and the two axes should be rotated synchronously for 360 °. Readings should be recorded every 45 °, and a reading difference of ≤ 0.02mm for three consecutive cycles is considered valid. The final radial deviation should be ≤ 0.05mm and the angle deviation should be ≤ 0.02mm/m.
Reserved thermal expansion compensation: When aligning in a cold state, make the center of the reducer side shaft slightly lower than the center of the motor shaft by 0.1-0.15mm, to offset the secondary deviation of the axis floating up after running and heating up.
Synchronous verification of tooth flank clearance: Measure the tooth flank clearance using the lead pressure method and control it within the range of 0.1~0.3mm to avoid meshing bias caused by shaft alignment deviation. The soft tooth surface has weak resistance to bias load, and exceeding the clearance limit will accelerate the plastic deformation of the tooth surface.
3、 Tightening and Dynamic Verification Specification
Bolt tightening requirements: Tighten the anchor bolts evenly in 2-3 diagonal steps, with a torque error of ≤ 5%, to avoid unilateral force causing axis displacement and rebound.
Static retest confirmation: Immediately retest the coaxiality after tightening, confirm that there is no rebound in the deviation and it is still within the tolerance range. It is strictly prohibited to start the machine without retesting.
Dynamic hot state verification: Run without load for 1-2 hours, and after the equipment is thermally stable, retest the vibration speed ≤ 4.5mm/s and temperature rise ≤ 40 ℃; After running on load for 2 hours, recalibrate again. If the change in thermal deviation is ≤ 0.02mm, it is considered qualified.